Description
ThePD-150 is designed to accommodate numerous applications, can be adjusted intelligently to any environments and virtually eliminating false detection.
On the front panel, the four selectable loop frequencies (20~80 KHz) can completely eliminate any crosstalk.
If intermittency happens or failed loops get self-healed, the detector will resume normal operation without manually reset the detector.
Power LED-Red, Fault LED-Green
Sensitivity: | 4 Levels | Operation Temp: | -40℃ To +70℃ |
Work Voltage: | 12-24VDC,85-265VAC | Loop Frequency: | 4 Setting(low,Med-low,Med-Hi,High) |
Visual Indications: | Housing Color: | Black, white Or OEM/ODM | |
Response Time: | 10-90MS | Loop Inductance: | 20-2000uh |
Weight: | 0.18KG | Relay Signal: | Presence Signal And Pulse Signal |
Ticket Dispensers Single Loop detector, Traffic Barrier Gate 10MS – 90MS
Application:
The PD-150 Enhanced single channel detectors can be used in a variety of applications in the parking and door / gate environments:
1. To arm card readers and ticket dispensers.
2. As a barrier/gate/door closing detector.
3. As a barrier/gate/door opening detector (Free exit).
4. To generate pulses for counting vehicles.
Description:
The loop consists of several loops of wire and consideration
should be giving to the loop sensitivity when installing on different surfaces. Setting the correct sensitivity allows the loop to operate with maximum detection. When detection occurs, the detector energizes 2 relays for the output (each can be configured individually). This energizing of the relay can be configured into different modes, by selecting the respective dip switch.
Sensitivity Selection
The sensitivity of the loop can be adjusted by the trim pot labeled “Sensitivity”. The user can select 4 different setting by turning the trim pot with 0 being the least sensitive and “4” being the most sensitive.
Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the loop detector.
The PD-150 vehicle loop detector is compatible with most gate operators. The PD-150 may be used in Center, Safety and Exit loop positions.Fifteen sensitivity settings allow for fine adjustment of the detection level.
Specifications:
PD-150:85-240VAC (50Hz-60Hz)
Loop Inductance
20-2000μH
Sensitivity
ΔL 0.01% to 2.56% with 16 Selectable Levels
Response Time
8~80 ms
EURO 11-pin connect
How to install the loop detector?
Keyword:vehicle detector, traffic detector, Double Loop Vehicle Detector, Vehicle Loop Wire, Automobile Sensor, vehicle loop detector installation, vehicle loop detector module
LD-152 EU market, Single channel Vehicle Loop Detector, the output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems, power:12-24VADC
power:12-24VADC
blommaw –
Increase in All Cause Mortality in Patients With Carbapenem Resistant Gram Negative Bacterial Infections see WARNINGS AND PRECAUTIONS Hypersensitivity Reactions see WARNINGS AND PRECAUTIONS Clostridioides difficile Associated Diarrhea CDAD see WARNINGS AND PRECAUTIONS Seizures and Other Central Nervous System Adverse Reactions see WARNINGS AND PRECAUTIONS priligy cvs